18 core medical transducer cable TR18B
As an ISO 13485 certified medical cabling innovator, Conectmed manufactures high-performance medical transducer cable solutions on master spools. Custom-engineered for multi-channel clinical diagnostic sensors, high-density telemetry arrays, and precision multi-parameter patient monitors, our premium 18 core braided wire (Model: TR18B) combines ultra-fine PFA-insulated conductor matrices with a high-coverage tinned copper shield. This structural architecture ensures absolute EMI/RFI isolation, safeguarding weak low-voltage sensor signals from external crosstalk while maintaining an ultra-soft profile.
technical specification
| Items | Specification | ||
| Products name | |||
| Model | TR118B | ||
| Conductor 1 | Material | Tinned copper or Copper Alloy | |
| Specification | 7/0.O3TSN | ||
| Insulation 1 | Material | PFA | |
| Nom.Thickness | 0.07 | ||
| Nom.O.D. | ø0.25士0.03 | ||
| Colour | White/Green/Yellow/Black/Blue/Brown/Orange/Red | ||
| Inner Filler | Material | Kevlar | |
| Conductor 2 | Material | Tinned copper or Copper Alloy | |
| Specification | 7/0.O3TSN | ||
| Insulation 2 | Material | PFA | PFA |
| Nom.Thickness | 0.11 | 0.11 | |
| Nom.O.D. | ø0.5士0.05 | ø0.5士0.05 | |
| Colour | White/Green/Yellow/Blue | Black/Brown/Orange/Red | |
| Groundwire | Material | Tinned copper or Copper Alloy | |
| Specification | 25/0.O5TSN | ||
| Isolation | Material | Aluminum leaf | |
| Outer Filler | Material | Contton Thread | |
| Outer Shield | Material | Tinned copper | |
| Specification | 16*12/0.O5TC | ||
| Jacket | Material | 80P-PVC | |
| Nom.Thickness | 0.81 | ||
| Nom.O.D. | ø4.8士0.10 | ||
| Colour | Black | ||
Why Sourcing Engineers Specify Our TR18B Transducer Variant:
Standard bulk multicore wires introduce massive capacitance fluctuations and structural static under continuous equipment manipulation. Our premium TR18B series resolves strict multi-channel sensor engineering thresholds:
* Extreme Signal Density: Integrates 18 isolated signal pathways protected under a single compact 4.8mm outer diameter, perfect for complex multi-parameter medical handles.
* Elite Flex-Life Matrix: Reinforced with internal structural fillers to absorb mechanical tension, preventing micro-conductor stretch or resistance drift during long-term field use.
* Automation-Ready Setup: Supplied on raw wholesale master spools, optimized for high-speed downstream precision factory stripping and micro-soldering to sensor array matrices.
Technical FAQ & Validation Timeline for Multi-Core Transducer Wires
Q1: How does Model TR18B protect delicate sensor data from ambient hospital noise?
A: The 18-core core array is enveloped in a premium aluminum isolation wrap combined with a high-density tinned copper over-braid shield (16*12/0.05TC). This configuration creates an absolute Faraday shield, draining high-frequency electromagnetic interference (EMI) and maintaining excellent signal-to-noise ratios.
Q2: Why is PFA utilized as the primary internal insulation material?
A: PFA (Perfluoroalkoxy) delivers elite dielectric stability. With a nominal insulation thickness of just 0.07mm, it minimizes capacitive loading between the 18 adjacent channels, ensuring fast, distortion-free response times for high-sensitivity physiological sensors.
🛑 Stop Letting Rigid Commodity Wires Compromise High-Sensitivity Transducer Signals.
Partner with an Agile, ISO 13485 Certified Multi-Core Sensor Cable Manufacturer.
If this 18 core braided medical transducer cable specification (TR18B) aligns with your sensor array hardware layout, fill out the form below to specify your required core variations or annual volume thresholds, and request your Free Factory Bulk Samples now!