24 Wire imaging cable for mri machines with12 Coax 32AWG And 12x 26AWG Signal Wire
The 24 Wire MRI Cable With 12 Coax 32AWG And 12x 26AWG Signal Wire;It is Imaging Cable for MRI Machines.We also provide other spec MRI cable with different coax numbers and signal wire numbers,such as 12 coax +20 signal wire,16 coax+16 DC wires…..It maybe used in 24-channel head coil for MR imaging
And we are experienced in medical imaging signal cables ,especially custom MRI cable for MRI rf coils



technical specification
Construction and material
| Item | Unit | Specified Value | ||||||||||||||||
| 32AWG Coaxial (A) | 26AWG Wire(B) | |||||||||||||||||
| Number of cores | – | 12 | 12 | |||||||||||||||
| Inner Conductor | Material | – | Silver plated Copper wire | |||||||||||||||
| Stranding | No./mm | 1/0.20 | 19/0.10 | |||||||||||||||
| Diameter(Nom.) | mm | 0.20 | 0.50 | |||||||||||||||
| Insulation | Material | – | FEP | FEP | ||||||||||||||
| Thick.(Nom.) | mm | 0.20 | 0.15 | |||||||||||||||
| Diameter | mm | 0.60±0.02 | 0.80±0.02 | |||||||||||||||
| Color | – | Nature | See Fig.1 | |||||||||||||||
| Braid Shielding | Material | – | Silver plated Copper wire | – | ||||||||||||||
| Strand Dia. (approx.) | mm | 0.08 | ||||||||||||||||
| Dia.(approx.) | mm | 0.92 | ||||||||||||||||
| Coverage | % | 90% | ||||||||||||||||
| Sheath | Material | – | FEP | |||||||||||||||
| Thick.(Nom.) | mm | 0.05 | ||||||||||||||||
| Diameter | mm | 1.18±0.03 | ||||||||||||||||
| Color | – | See Fig.1 | ||||||||||||||||
| Assembly Diameter(Nom.)1 | mm | 3.3(See Fig.1) | ||||||||||||||||
| Assembly Diameter(Nom.)2 | 5.88 | |||||||||||||||||
| Tape1 | Material | – | PTFE | |||||||||||||||
| Thick.(Nom.) | mm | 0.05 | ||||||||||||||||
| Diameter | mm | 6.08 | ||||||||||||||||
| Braid Shielding | Material | – | Tinned copper wire | |||||||||||||||
| Dia.(approx.) | mm | 0.12 | ||||||||||||||||
| Coverage | % | 85% | ||||||||||||||||
| Tape2 | Material | – | PTFE | |||||||||||||||
| Thick.(Nom.) | mm | 0.05 | ||||||||||||||||
| Diameter | mm | 6.76 | ||||||||||||||||
| Jacket | Material | – | TPU | |||||||||||||||
| Thickness (Nom.) | mm | 0.85 | ||||||||||||||||
| Diameter | mm | 8.50±0.20 | ||||||||||||||||
| Color | – | Gray/Custom | ||||||||||||||||
Technical Data:
• Operating voltage:30V
• Test voltage:AC 1.0kV/1min
• Temperature range:-40°C ~+ 80°C
• Insulation resistance B(20°C):≥ 100MOhm x km
• Characteristic impedance:50±3Ω
• Delay:4.9ns/m
• VSWR:≤1.3(12~300MHz)
• Attenuation typ.(dB/100m):12MHz≤21.7,63MHz≤49.5,
123MHz≤69.1,135MHz≤72.5,300MHz≤108.8 ,350MHz≤155.2,
400MHz≤175.1,450MHz≤190.2,500MHz≤210.1
There are other types of MRI compatible Multi coaxial cable optional.

32 wire Multi coax cable with 16x 50ohm coaxial cable RG 178 and 16x 26AWG wire

32 wire custom rf cables with 12 coaxial cable 50 Ohm 32AWG and 20X 28AWG wire

Multi Core RF Coax Cable 10 Coax RG178 For MRI RF Coil

26 wire MRI RF Coaxial Cable with 8 coax 32AWG and 18x 28AWG Signal wire OD 8.4mm