30 AWG 7 Conductor Shielded Cable 3 Twisted Pair Plus 1 Single Wire TPU Jacket
This 7 Conductor Shielded Cable 3 Twisted Pair Plus 1 Single Wire 30 AWG ,TPU Jacket ,there is also 7 Core shielded cable with an Conducting layer for low noise purpose.
Compare with Ethernet Cable (Cat5 Cat6),this cable is one wire less.
The 7 Conductor Shielded Cable with 3 twisted pairs and 1 single wire, and a spiral shield can be used for various applications in the medical device industry.
One potential use could be in the transmission of signals and power between different components of a medical device. The twisted pairs can be used for differential signal transmission, which can reduce electromagnetic interference and improve signal integrity. The single wire can be used for power transmission, while the spiral shield can protect against external electromagnetic interference.
Another potential use could be in the sensing and monitoring of physiological signals from patients. The twisted pairs can be used for the transmission of signals from sensors, such as ECG or EEG electrodes, while the shield can protect against interference from other electrical devices in the environment.
Overall, the 7 Conductor Shielded Cable can provide reliable and efficient signal transmission and power delivery in medical devices, while also protecting against external interference.
technical specification
Items | Specification | ||
Products name | 30 AWG 3P of Twisted Line and 1 core TPU Jacket OD 4.1 | ||
Model | CU207S-4.1 | ||
AWG | 30 AWG | ||
Conductor | Material | TINNED COPPER | |
Specification | 7/0.10TC | ||
Insulation | Material | PVC | |
Nom.Thickness | |||
Nom.O.D. | ø0.60士0.02 | ||
Colour | Brown/Pink/Gray/Yellow/Green/Red/Blue | ||
Filler | Material | 1000D KEVLAR | |
Separator | Material | PTFE Tape | |
Shield | Material | Tinned copper | |
Specification | 60士5/0.10TC | ||
Coverage | >90% | ||
Wrapper | Material | 10mm non-woven fabric | |
Jacket | Material | TPU (1185) | |
Nom.Thickness | |||
Nom.O.D. | 4.10±0.10mm | ||
Colour | Gray | ||
Main Properties | |||
1. Insulation resistance: DC500V, 1 minute, more than 100MΩ/3M between wires&Wires and between wires & shield; 2. Withstanding voltage test: AC1000V, 3m leakage current is less than 0.25mA. DC4000V less than 0.5mA between wires & shield & outer Jacket ; DC5000V 60S less than 0.203mA between wires & shield and outer Jacket 3. Bending test: load 530G, left and right 90 degrees, 40 times/min, more than 5000 times. Hanging length 300mm R: 25.4mm. 4. Pull-off force greater than 68N 5. Distributed capacitance: 100PF/M (between core wires) 450PF/M (between shields) |